Analizador de trazas de Nitrógeno

Analizador de trazas de Nitrógeno - AZ 8001

The AZ 8000 is our online Trace Nitrogen Analyser for Argon and Helium.

General

The AZ 8001 is a Trace Nitrogen Analyser. Its unique design brings reliability and accuracy needed for such measurement. Its own Plasma Emission Detector System extends the lifetime of the cell. This Duty Cycle Controlled System has the property to decrease contamination and coating inside the plasma cell giving a more efficient, reliable y accurate analyser.

Aplicaciones

Descubra cuál analizador(s) necesario para su solicitud analítica. Consulte la aplicación aquí !

Algunas referencias globales

Compañía Tipo de Analizador Modelo Impurezas
Air Products (Francia) Helio AZ 8000 N2
Air Liquide (Francia) Argón AZ 8000 N2
Linde (China) Argón AZ 8000 N2
Air Liquide (Egypt) Argón AZ 8000 N2

Especificaciones Técnicas

Tipo de detectorPlasma Emission Detector design based on a Duty Cycle Controlled System
Three ranges
0 – 1 ppm
0 – 10 ppm 0 – 100 ppm
Display resolution to 0.01 ppm
Display resolution to 0.1 ppm
Display resolution to 1 ppm
Other range possible up to 10000 ppm
Repeatability
Características standard Manual or autoranging (user selectable)
Microprocessor controlled
Touchscreen 7” HDMI TFT Display
Self diagnosis system with auto-resolve alarm
LAN/Web control
4-20 mA isolated output
Alarm Historic
Safe calibration procedure to avoid any bad calibration
Digital ouputs for remote monitoring:
(all dry relay contacts)
- System status (1 output)
- Range in use (3 output)
- Calibration in use (1 output)
OpcionesInternal sampling system for zero, span and sample with remote capabilities
Puerto Serie: RS-232/422/485/ Pro bus
2 alarm outputs (user programmable set point)
Conexiones de GasesMuestra: 1/8’’ compressing ttings
Venteo1/8" compressing fitting
Gas de calibraciónZero: Purified gas (Getter)
Span8.0 a 9.5 ppm N2 (application dependent)
Sample flow requirements75 a 200 ml/min
PrecisiónBetter than +- 1% full scale
Max operating pressure30psig
Min. operating pressure3psig
Temperatura de operación10 °C to 45 °C
Alimentación115 VAC, 50 - 60 Hz or 220 VAC, 50 - 60 Hz
Consumo de energíaMaximum 40 watts
Deriva
Weight13 kg

Características

Unique Plasma Emission Detector
Large scale measurement
4-20 mA output (standard)
Free maintenance
LAN/Web control
Fast purging time
Low sample consumption
3U cabinet